Sartorius Group - SIGMA 6-15 and 6K15
by Sartorius Group
Do you have a estrutural plattform where is to mounten all devices of the OIL CENTRIFUGE SIGMA 6-15H model: '6-15/9 K15 - 09/05/01' ??
1 Reply SIGMA 6-15 CENTRIFUGE?
erro 25 !a drive problem ! Someone could help me to solve this problem ??
1 Reply GOSTARIA DE SABER QUAL É O TEMPO DE AQUECIEMENTO PARA ATINGIR 60C NESTA centrifuga MODELO 6-15h.
E QUAL A TEMPERATURA NORMAL DE TRABALHO DA MESMA.
GRATO,
UDENIR
1 ReplyI HAVE A SIGMA 6K15 CENTRIFUGE, IT HAS A PROBLEM WITH THE DOOR. WHEN THE DOOR IS CLOSED THE SENSOR START AND CLOSE THE DOOR, IN A FEW SECONDS THE DISPLAY SENDS A MESSAGE 'PROBLEM WITH THE DOOR OPEN. TURN ON AND OF THE POWER SWITCH' PROBLEM 78. I FOLLOW THE INSTRUCTION THAT APPEARS IN THE DISPLAY AND THE PROBLEM STARTS AGAIN AND AGAIN. I REVIEWED THE MANUAL AND THIS PROBLEM DOES NOT APPEAR SO I NEED YOUR HELP FOR RESOLVE THIS PROBLEM. THANKS[i]Originally asked by HECTOR VALDEZ via email[/i]
0 RepliesPlease, My question isWaht to do with TH e error 43, imbalance offset fail? If we switch on the centrifuge 6K15 and before deposing any plate we get this error? Thank you for your help
One moment please...
Sartorius Group - SIGMA 6-15 and 6K15
by Sartorius Group
DESCRIPTION
High-performance laboratory centrifuge for swing-out and angle rotors, programmableFORUMSView All (5)
Ask a New Question0Replies6 years ago | 6 years agoSIGMA 6-15/9 K15 modelo 09/05/01 Do you have a estrutural plattform where is to mounten all devices of the OIL CENTRIFUGE SIGMA 6-15H model: '6-15/9 K15 - 09/05/01' ?? Reply |
-LETTEC RJ 6 years ago | 6 years agoerro 25 SIGMA 6-15 CENTRIFUGE? erro 25 !a drive problem ! Someone could help me to solve this problem ?? Reply |
1Reply6 years ago | 6 years agoDUVIDAS GOSTARIA DE SABER QUAL É O TEMPO DE AQUECIEMENTO PARA ATINGIR 60C NESTA centrifuga MODELO 6-15h. E QUAL A TEMPERATURA NORMAL DE TRABALHO DA MESMA. GRATO, UDENIR Reply |
DOCUMENTS / MANUALSView All
FEATURES
SIGMA 6K15
- High volume refrigerated bench top or movable floor centrifuge.
- Maintenance-free brushless drive motor.
- Speed range between 100 rpm and 15.000 rpm selectable in steps of 1 rpm.
- Free programming of all run parameters possible.
- Automatic rotor identification prevents the rotor from overspeeding.
- Simple single-knob control for all centrifugation parameters.
- Display of all rotors|bucket combinations and their max. speed and gravitational field.
- Program memory for 50 data sets.
- Symbol keys for Start, Stop and Lid.
- Efficient refrigerating machine for temperatures between –20 °C and +40 °C, possibility of precooling the rotors during standstill.
- Motorized lid lock for optimal operating convenience.
- Reliable drive system.
- Produced according to national and international safety regulationsSIGMA 6-15
- Air-cooled high volume bench top centrifuge.
- Design and operation nearly identical with SIGMA 6K15, but without refrigeration system.
SERIES MODELS
Maximum Speed | 13500 rpm min-1 |
Orientation | Benchtop |
Height | 425 mm |
Length | 685 mm |
Weight | 116 kg |
Width | 574 mm |
Additional Specifications | Power consumption drive: 1200 W Kinetic Energy max.: 106.950 Nm |
Maximum Speed | 15000 rpm min-1 |
Orientation | Benchtop |
Height | 425 mm |
Length | 685 mm |
Weight | 158 kg |
Width | 780 mm |
Additional Specifications | Power consumption drive: 1200 W Kinetic Energy max.: 154.007 Nm |